The dimensions of skin fragments dispersed into the air during activity

活动期间散布到空气中的皮肤碎片尺寸

阅读:1

Abstract

There was a 1000-fold difference between the highest and the lowest mean rate of dispersal of bacteria-carrying particles during exercise among a group of three male and three female subjects. Differences in the numbers of skin fragments dispersed and in the proportion of these carrying bacteria were almost equally responsible for this. Since there is little difference between individuals in the rate of skin replacement the differences in the rates of dispersal of skin fragments during exercise must reflect large variations in the amount of skin surface removed in other ways. The skin fragments dispersed had a wide size range extending below 5 micrometer for the minimum projected diameter (MPD). The median MPD was about 20 micrometer with 7-10% less than 10 micrometer. Many of the particles could therefore pass freely through tightly woven fabrics with pores up to 10-15 micrometer which might seem to be impenetrable to whole corneocytes, typically larger than 30 X 40 micrometer in the hydrated state.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。