The Use of a Handheld Ultrasound Device to Measure Humeral Retrotorsion in Baseball and Softball Athletes: A Validation Study

使用手持式超声设备测量棒球和垒球运动员肱骨后倾角:一项验证性研究

阅读:2

Abstract

BACKGROUND: Relative humeral retrotorsion (rHRT) is an osseous adaptation in overhead athletes garnered from repetitive overhead throwing. Accurate measurement of anatomic humeral retrotorsion (aHRT) is important as it aids in the determination of rHRT, which influences glenohumeral range of motion profiles. While computed tomography scans are the gold standard for assessing aHRT, their limited clinical utility has driven interest in accessible alternatives, such as diagnostic ultrasound. PURPOSE/HYPOTHESIS: The purpose of this study was to validate a handheld ultrasound device (HH-US) as a clinically accessible tool to measure aHRT in baseball and softball athletes. It was hypothesized that a HH-US device will be reliable and valid when quantifying aHRT compared with an established benchmark, diagnostic musculoskeletal ultrasound (MSK-US). STUDY DESIGN: Cohort study (Diagnosis); Level of evidence, 3. METHODS: Data were collected from collegiate baseball and softball athletes at 2 local universities. Participants were uninjured at the time of testing and over 17 years old. Anatomic HRT was measured bilaterally using both MSK-US (GE Venue Go) and handheld ultrasound (GE Vscan Air) using previously established methods. The intraclass correlation coefficient, standard error of measure, and minimal detectable change, as well as Bland-Altman plots, were used to assess reliability and agreement between devices, respectively. RESULTS: A total of 93 athletes were included in this study. HH-US had excellent intrarater reliability (ICC(2),(1) = 0.98; 95% CI, 0.94-0.97; SEM(90) = 1.77°; and MDC(90) = 4.12°). There was acceptable agreement between the HH-US and MSK-US. The mean difference between devices was -0.63° and 0.48° for the throwing and nonthrowing arms, respectively. Analysis of Bland-Altman plots demonstrated no significant bias across the range of measurements. HH-US measurements were completed in <2 minutes. CONCLUSION: Our study showed that HH-US provides a reliable and valid measurement of aHRT in comparison to MSK-US and may be an accessible option for clinicians evaluating overhead athletes. Given its strong agreement with established methods, HH-US offers an efficient and cost-effective alternative to MSK-US when measuring aHRT in baseball and softball athletes.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。