Reliability and Reproducibility of the EOS 3D Imaging System in Measuring TT-TG Distance in Patients With Recurrent Patellar Dislocation

EOS 3D成像系统测量复发性髌骨脱位患者TT-TG距离的可靠性和可重复性

阅读:2

Abstract

BACKGROUND: In clinical practice, preoperative radiographic assessment of the tibial tuberosity-trochlear groove (TT-TG) distance in patients with recurrent patellar dislocation (RPD) typically relies on conventional computed tomography (CT). A novel EOS imaging system may be a new option for measuring the TT-TG, which provides less radiation and costly time to perform. PURPOSE: To determine the reliability and reproducibility of the EOS 3-dimensional (3D) imaging system to measure TT-TG values. STUDY DESIGN: Cohort study (Diagnosis); Level of evidence, 2. METHODS: Data from 34 patients (36 knees) diagnosed with RPD in our sports medicine department were retrospectively analyzed. Two senior radiologists independently measured the alignment of the patients' lower limbs via EOS images. The TT-TG values measured by EOS 3D images and CT scans were compared. To evaluate intrareader reliability, measurements were repeated on 2 separate occasions ≥3 days apart and intraclass correlation coefficients (ICCs) and Bland-Altman plots were calculated. RESULTS: When lower-limb alignment was measured with EOS, there were no statistically significant differences in the femoral and tibial lengths (P = .87 and P = .78, respectively), femoral offset (P = .83), knee joint varus and valgus angles (P = .73), femoral and tibial mechanical angle (P = .70 and P = .83, respectively), and femorotibial torsion angles (P = .82) measured by the 2 radiologists. Excellent intraobserver ICC (>0.75) was observed. The TT-TG measurements using EOS 3D were 18.4 ± 4.2 mm (radiologist 1) and 18.4 ± 3.5 mm (radiologist 2), while the corresponding values from CT were 19.2 ± 4.0 mm and 18.5 ± 3.7 mm, respectively. The measurements between EOS and CT showed good intrarater consistency (ICC > 0.7). Bland-Altman analysis revealed mean differences of 0.743 mm and 0.081 mm between the 2 methods, with >91% of data points falling within ±1.96 SD, indicating strong agreement between the 2 measurement techniques. CONCLUSION: Our study showed that the EOS 3D imaging system provides reliable and reproducible TT-TG measurements comparable with CT. This technology has the potential to serve as an alternative method for assessing lower-limb alignment and TT-TG values in patients with RPD.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。