Comparison of Anterior Center-Edge Angle Measured From the Acetabular Sourcil Versus the Anterior Bone-Edge of the Acetabulum: A Descriptive Laboratory Study

髋臼前缘中心角测量方法与髋臼前缘中心角测量方法的比较:一项描述性实验室研究

阅读:1

Abstract

BACKGROUND: Measuring anterior hip coverage on false-profile (FP) radiographs is important for judging anterior hip coverage. Conventionally, the anterior center-edge angle (ACEA) is measured from the anterior edge of the acetabular sourcil (sourcil ACEA); however, the anterior bone edge is also used as the anterior landmark. PURPOSE: To determine whether the sourcil ACEA or the bone-edge ACEA better represents the anterior coverage of the hip joint. STUDY DESIGN: Descriptive laboratory study. METHODS: We retrospectively observed 49 hips in 49 patients who underwent isolated periacetabular osteotomy. The sourcil ACEA was measured according to the standard procedure. Then, 3-dimensional (3D) volumetric models were made from computed tomographic data. The acetabular surface of the 3D model was labeled and projected onto a simulated FP radiograph, enabling the edge of the acetabulum to be identified. This simulated FP radiograph was used to measure the "true ACEA," as well as the sourcil ACEA and the bone-edge ACEA, and the 3 measurements were compared. Statistical analysis was performed-including testing for normal distribution, measuring interobserver agreement, evaluating differences between measurements, and validating correlation. RESULTS: The mean sourcil ACEA was 8.6° (range, -3.9° to 31.7°) smaller than that of the true ACEA (P < .001); there was a strong correlation (r = 0.81; P < .001) between the 2. The mean bone-edge ACEA was 16.8° (range, -1.7° to 45.4°) greater than that of the true ACEA (P < .001); there was a moderate correlation (r = 0.57; P < 0.001) between the 2. CONCLUSION: Both the sourcil ACEA and bone-edge ACEA differed from the true ACEA. However, compared with the bone-edge ACEA, the sourcil ACEA was numerically closer to the true ACEA and had a stronger correlation with it . CLINICAL RELEVANCE: While the exact edge of the true bearing surface of the articular cartilage may not be visible on the FP radiograph, the sourcil ACEA can be effectively utilized as a reliable surrogate when evaluating the anterior acetabular coverage in hip preservation surgery.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。