Reliability and Reproducibility of a Novel Grading System for Lesions of the Ligamentous-Fossa-Foveolar Complex in Young Patients Undergoing Open Hip Preservation Surgery

针对接受开放式髋关节保留手术的年轻患者,一种新型韧带-关节窝-小脑凹复合体损伤分级系统的可靠性和可重复性

阅读:1

Abstract

BACKGROUND: Several classification systems based on arthroscopy have been used to describe lesions of the ligamentum teres (LT) in young active patients undergoing hip-preserving surgery. Inspection of the LT and associated lesions of the adjuvant fovea capitis and acetabular fossa is limited when done arthroscopically but is much more thorough during open surgical hip dislocation. Therefore, we propose a novel grading system based on our findings during surgical dislocation comprising the full spectrum of ligamentous-fossa-foveolar complex (LFFC) lesions. PURPOSE: To determine (1) intraobserver reliability and (2) interobserver reproducibility of our new grading system. STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 3. METHODS: We performed this validation study on 211 hips (633 images in total) with surgical hip dislocation (2013-2021). We randomly selected 5 images per grade for each LFFC item to achieve an equal representation of all grades (resulting in 75 images). The ligament, fossa, and fovea were subcategorized into normal, inflammation, degeneration, partial, and complete defects. All surgeries were performed in a standardized way by a single surgeon. The femur was disarticulated using a bone hook, the LT was inspected, documented and resected, then the fossa and fovea were documented with the femoral head in full dislocation using a 70° arthroscope. Six observers with different levels of expertise in hip-preserving surgery independently conducted the measurements twice, and intraclass correlation coefficients (ICC) were calculated to determine (1) intraobserver reliability and (2) interobserver reproducibility of the novel grading system. RESULTS: For intraobserver reliability, excellent ICCs were found in both the junior and the experienced raters for grading the ligament, fossa, fovea, and total LFFC (ICCs ranged from 0.91 to 0.99 for the LFFC score). We found excellent interobserver reproducibility between raters for all items of the LFFC (all interobserver ICCs ≥ 0.76). CONCLUSION: Our new grading system for lesions of the LFFC is highly reliable and reproducible. It covers the full spectrum of damage more precisely than arthroscopic classifications do and offers a scientific basis for standardized intraoperative evaluation.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。