Incidence and Factors Affecting the Occurrence of Lateral Hinge Fracture After Medial Opening-Wedge High Tibial Osteotomy

内侧开放楔形高位胫骨截骨术后外侧铰链骨折的发生率及影响因素

阅读:1

Abstract

BACKGROUND: Few clinical studies have reported the predictors of lateral hinge fracture (LHF) after medial opening-wedge high tibial osteotomy (MOWHTO). PURPOSE/HYPOTHESIS: The purpose was to compare the incidence of LHF on plain radiographs versus computed tomography (CT) scans and to investigate the factors related to the development of LHF after MOWHTO. We hypothesized that (1) a higher LHF detection rate would be seen on CT scans versus plain radiographs and (2) LHF incidence would be related to opening gap width and hinge position. STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 3. METHODS: A total of 97 MOWHTO cases were included. The presence and types of LHF were determined from plain radiographs and CT scans. Radiographic parameters were measured on plain radiographs taken 6 weeks postoperatively. Anterior and posterior opening gap widths, coronal and sagittal osteotomy slopes, and fibular height were calculated from CT scans. The wedge-hinge relationship and the zone of hinge position were assessed, and the patient and radiographic factors related to LHF occurrence were evaluated. RESULTS: Seventeen LHF cases (20.5%) were detected on plain radiographs, while significantly more (37 cases; 44.6%) were found on CT scans (P = .001). Based on Takeuchi classification, 28 LHF cases were considered type 1, 7 were type 2, and 2 were type 3. Logistic regression analysis revealed that opening gap width (odds ratio, 1.615; 95% confidence interval, 1.232-2.118; P = .001) and posterior opening gap width (odds ratio, 3.731; 95% confidence interval, 1.642-4.351; P = .008,) differed significantly between patients with versus without LHF. Other patient and radiographic factors were not significantly related to LHF occurrence. Receiver operating characteristic curve analysis identified the opening gap width cutoff values for LHF as 11.0 mm (area under the curve, 0.81; sensitivity, 78.4%; specificity, 73.9%). CONCLUSION: The incidence of LHF after MOWHTO can be underestimated on plain radiographs compared with CT scans. Only large opening gap width, especially posterior gap width, was found to have a statistically significant relationship with occurrence of LHF. Therefore, special caution for possible LHF may be needed if a large correction is planned.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。