Suture Tape Augmentation of Screw Fixation Reduces Fragment Migration in Tibial Tubercle Osteotomy: A Biomechanical Study

缝合带增强螺钉固定可减少胫骨结节截骨术中的骨碎片移位:一项生物力学研究

阅读:1

Abstract

BACKGROUND: Tibial tubercle osteotomy (TTO) is a complex surgical procedure with a significant risk of complications, which include nonunion and tibial fracture. PURPOSE: To determine whether an additional suture tape augmentation can provide better biomechanical stability compared with standard screw fixation. STUDY DESIGN: Controlled laboratory study. METHODS: Five matched pairs of human cadaveric knees were divided into 2 groups: the first group underwent standard TTO fixation with 2 parallel screws (standard group). The second group underwent a novel fixation technique, in which a nonabsorbable suture tape (FiberTape) in a figure-of-8 construct was added to the standard screw fixation for extra stabilization in the inferior-superior direction (augmented group). The specimens were biomechanically tested using a multistep cyclic loading protocol from 400 N up to 800 N to simulate the rehabilitation process. Tubercular fragment migration of >50% of the initial distalization length was defined as clinical failure. A pull-to-failure test was applied to the specimens that survived cyclic loading. Tubercular fragment displacement during cyclic loading and pull-to-failure force were recorded and compared between the 2 groups. RESULTS: Two specimens of the standard group exhibited clinical failure during cyclic loading to 400 N. All other specimens survived cyclic loading to 800 N. The augmented group showed less cyclic tubercular fragment displacement after every load level compared with the standard group, with statistically significant differences starting from 500 N (P < .05; power > 0.8). Mean ± standard deviation tubercular fragment displacement at the end of cyclic loading was 2.56 ± 0.82 mm for the augmented group and 5.21 ± 0.51 mm for the standard group. Mean ultimate failure load after the pull-to-failure test was 2475 ± 554 N for the augmented group and 1475 ± 280 N for the standard group. CONCLUSION: The specimens that underwent suture tape augmentation showed less tubercular fragment displacement during cyclic loading and higher ultimate failure forces compared with those that underwent standard screw fixation. CLINICAL RELEVANCE: The augmentation technique could potentially increase the success of a TTO.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。