Tibial Tunnel Placement in ACL Reconstruction Using a Novel Grid and Biplanar Stereoradiographic Imaging

利用新型网格和双平面立体放射成像技术进行前交叉韧带重建中的胫骨隧道定位

阅读:2

Abstract

BACKGROUND: Nonanatomic graft placement is a frequent cause of anterior cruciate ligament reconstruction (ACLR) failure, and it can be attributed to either tibial or femoral tunnel malposition. To describe tibial tunnel placement in ACLR, we used EOS, a low-dose biplanar stereoradiographic imaging modality, to create a comprehensive grid that combines anteroposterior (AP) and mediolateral (ML) coordinates. PURPOSE: To (1) validate the automated grid generated from EOS imaging and (2) compare the results with optimal tibial tunnel placement. STUDY DESIGN: Descriptive laboratory study. METHODS: Using EOS, 3-dimensional models were created of the knees of 37 patients who had undergone ACLR. From the most medial, lateral, anterior, and posterior points on the tibial plateau of the EOS 3-dimensional model for each patient, an automated and personalized grid was generated from 2 independent observers' series of reconstructions. To validate this grid, each observer also manually measured the ML and AP distances, the medial proximal tibial angle (MPTA), and the tibial slope for each patient. The ideal tibial tunnel placement, as described in the literature, was compared with the actual tibial tunnel grid coordinates of each patient. RESULTS: The automated grid metrics for observer 1 gave a mean (95% CI) AP depth of 54.7 mm (53.4-55.9), ML width of 75.0 mm (73.3-76.6), MPTA of 84.9° (83.7-86.0), and slope of 7.2° (5.4-9.0). The differences with corresponding manual measurements were means (95% CIs) of 2.4 mm (1.4-3.4 mm), 0.5 mm (-1.3 to 2.2 mm), 1.2° (-0.4° to 2.9°), and -0.4° (-2.1° to 1.2°), respectively. The correlation between automated and manual measurements was r = 0.78 for the AP depth, r = 0.68 for the ML width, r = 0.18 for the MPTA, and r = 0.44 for the slope. The center of the actual tibial aperture on the plateau was a mean of 5.5 mm (95% CI, 4.8-6.1 mm) away from the referenced anatomic position, with a tendency toward more medial placement. CONCLUSION: The automated grid created using biplanar stereoradiographic imaging provided a novel, precise, and reproducible description of the tibial tunnel placement in ACLR. CLINICAL RELEVANCE: This technique can be used during preoperative planning, intraoperative guidance, and postoperative evaluation of tibial tunnel placement in ACLR.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。