Multimodal Ultrasound Versus MRI for the Diagnosis and Monitoring of Achilles Tendinopathy: A Prospective Longitudinal Study

多模态超声与磁共振成像在跟腱病诊断和监测中的比较:一项前瞻性纵向研究

阅读:1

Abstract

BACKGROUND: The diagnosis and monitoring of Achilles tendinopathy with imaging are challenging. There is a lack of studies comparing the diagnostic accuracy of magnetic resonance imaging (MRI), brightness mode ultrasound (B-mode), and power Doppler ultrasound with recent technologies such as ultrasound tissue characterization (UTC) and shear wave elastography (SWE). PURPOSE: To assess whether SWE and UTC, which offer quantitative values, show a superior diagnostic accuracy and capacity to detect structural improvement in Achilles tendinopathy compared with MRI, B-mode, or power Doppler. STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 2. METHODS: Patients with insertional (n = 28) and midportion (n = 38) Achilles tendinopathy were evaluated at baseline and 6-month follow-up using MRI, B-mode, power Doppler, SWE, and UTC. Asymptomatic controls (n = 37) were evaluated at T (0). Diagnostic accuracy was analyzed based on a quantitative receiver operating characteristic (ROC) analysis with quantitative cutoff values (anteroposterior diameter, Öhberg score, UTC echo type, Young modulus) and by semiquantitative Likert scale-based assessment of experienced physicians. RESULTS: For diagnosing insertional Achilles tendinopathy, semiquantitative MRI and power Doppler were most favorable (diagnostic accuracy, 95%), while the cross-sectional area of MRI revealed 89% accuracy in the ROC analyses (area under the curve [AUC], 0.911; P < .001). For diagnosing midportion Achilles tendinopathy, semiquantitative MRI and B-mode were most favorable (diagnostic accuracy, 87%), while UTC echo types 3 and 4 revealed 86% and 87% accuracy, respectively, in the ROC analyses (AUC, 0.911 and 0.941, respectively; P < .001). However, for quantitative and semiquantitative evaluation of diagnostic accuracy in both insertional and midportion Achilles tendinopathy, there was no significant difference in favor of one imaging modality over the others. Compared with baseline, only SWE showed a significant change at the 6-month follow-up (P = .003-.035), but there were only fair to poor monitoring accuracies of 71% (insertion) and 60% (midportion). However, compared with the other modalities, the monitoring accuracy of SWE was significantly higher (P = .002-.039). CONCLUSION: There was no statistically significant difference in favor of one imaging modality over the others, but MRI revealed the highest overall diagnostic accuracy for the diagnosis of both insertional and midportion Achilles tendinopathy.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。