Passive Knee Stability After Anterior Cruciate Ligament Reconstruction Using the Endobutton or ToggleLoc With ZipLoop as a Femoral Fixation Device: A Comparison of 1654 Patients From the Danish Knee Ligament Reconstruction Registry

使用Endobutton或ToggleLoc加ZipLoop作为股骨固定装置进行前交叉韧带重建术后被动膝关节稳定性:来自丹麦膝关节韧带重建登记处的1654例患者的比较

阅读:1

Abstract

BACKGROUND: Biomechanical studies show varying results regarding the elongation of adjustable fixation devices. This has led to growing concern over the stability of the ToggleLoc with ZipLoop used in anterior cruciate ligament (ACL) reconstruction (ACLR) in vivo. PURPOSE/HYPOTHESIS: The purpose of this study was to compare passive knee stability 1 year after ACLR in patients in whom the Endobutton or ToggleLoc with ZipLoop was used for femoral graft fixation. The hypothesis was that the ToggleLoc with ZipLoop would be inferior in knee stability to the Endobutton 1 year after primary ACLR. STUDY DESIGN: Cohort study; Level of evidence, 2. METHODS: Data from 3175 patients (Endobutton: n = 2807; ToggleLoc with ZipLoop: n = 368) were included from the Danish Knee Ligament Reconstruction Registry (DKRR) between June 2010 and September 2013. Data were retrieved from standardized ACL forms filled out by the operating surgeon preoperatively, during surgery, and at a clinical examination 1 year after surgery. Passive knee stability was evaluated using 1 of 2 arthrometers (Rolimeter or KT-1000 arthrometer) and the pivot-shift test. Using the same database, the number of reoperations performed up to 4 years after primary surgery was examined. RESULTS: Full data were available for 1654 patients (Endobutton: n = 1538; ToggleLoc with ZipLoop: n = 116). ACLR with both devices resulted in increased passive knee stability (P < .001). Patients who received the ToggleLoc with ZipLoop were found to have a better preoperative (P = .005 ) and postoperative (P < .001) pivot-shift test result. No statistically significant difference regarding the number of reoperations (P = .086) or the time to reoperation (P = .295) was found. CONCLUSION: Patients who underwent fixation with the ToggleLoc with ZipLoop had improved passive knee stability 1 year after surgery, measured by anterior tibial translation and pivot-shift test results, similar to patients who underwent fixation with the Endobutton. No difference was seen in knee stability or reoperation rates between the 2 devices.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。