Measurement of Tibial Tuberosity-Trochlear Groove Offset Distance by Weightbearing Cone-Beam Computed Tomography Scan

负重锥形束计算机断层扫描测量胫骨结节-滑车沟偏移距离

阅读:1

Abstract

BACKGROUND: Computed tomography (CT) scans are useful for objectively measuring bone alignment because they show bone detail particularly well, and these scans have been used extensively to assess patellar orientation. The tibial tubercle-trochlear groove (TT-TG) offset distance has been shown to be influenced by knee flexion and weightbearing, yet conventional CT scans are obtained with the subject relaxed, supine, and with the knee in full extension. A new cone-beam CT scanner has been designed to allow for weightbearing images, potentially providing a more physiologically relevant assessment of patellofemoral alignment. PURPOSE/HYPOTHESIS: The purpose of this study was to measure the TT-TG offset in healthy individuals without any history of knee complaints when CT scans were obtained while fully weightbearing on a flexed knee. Our hypothesis was that the TT-TG offset measurement in these healthy knees would be reproducible and less than the historically reported normal range. STUDY DESIGN: Cross-sectional study; Level of evidence, 3. METHODS: Twenty healthy volunteers without any history of knee complaint were recruited to undergo a weightbearing cone-beam CT scan of the knee flexed at 30°. The scans were reviewed by a radiologist and an orthopaedic surgeon, and TT-TG offset was measured using the digital tools of a picture archiving and communication system. Paired t tests were used to compare TT-TG offset on 2 separate occasions for both raters. Inter- and intrarater reliability were assessed using a 2-way mixed-effects model intraclass correlation coefficient with corresponding 95% confidence intervals for TT-TG offset. RESULTS: The mean TT-TG offset was 2.7 mm. There were no statistically significant differences in TT-TG offset between raters (P(rater1) = .70; P(rater2) = .49) and time of read (P(time1) = .83; P(time2) = .19). Good to moderate interrater reliability was found at the time of both reads, and good intrarater reliability was found for both raters. CONCLUSION: When measured by CT scan and obtained from a subject while weightbearing on a flexed knee, the TT-TG offset is reproducible and the distance is less than that obtained via a conventional CT scan.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。