Comparison of 2 Radiographic Techniques for Measurement of Tibiofemoral Joint Space Width

两种测量胫股关节间隙宽度的放射影像学技术的比较

阅读:1

Abstract

BACKGROUND: No consensus is available regarding the best method for measuring tibiofemoral joint space width (JSW) on radiographs to quantify joint changes after injury. Studies that track articular cartilage thickness after injury frequently use patients' uninjured contralateral knees as controls, although the literature supporting this comparison is limited. PURPOSE: (1) To compare JSW measurements using 2 established measurement techniques in healthy control participants and (2) to determine whether the mean JSW of the uninjured contralateral knee in a cohort with anterior cruciate ligament (ACL) reconstruction is different from that obtained from a true control population. STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 2. METHODS: Medial and lateral JSWs were measured on standardized, bilateral, semiflexed metatarsophalangeal positioning, posteroanterior radiographs of 60 healthy individuals (26 females; mean ± SD age, 25 ± 6.2 years; no history of knee injury) via 2 published techniques: a computerized surface-delineation method (surface-fit method) and a manual digitization method (midpoint method). Bland-Altman method was used to examine the agreement between JSW measurements obtained with the 2 methods and to examine the agreement between measurements obtained on left and right knees within a participant for each measurement method. Within- and between-participant variance components and intraclass correlation coefficients (ICCs) were computed for JSW measurements corresponding to each method. Two-sample t tests were used to compare the surface-fit method measurements of mean JSW of the true control group (n = 60) with the previously published mean JSW measurements from the Multicenter Orthopaedics Outcomes Network (MOON) nested cohort of 262 contralateral uninjured knees 2 to 3 years after ACL reconstruction. RESULTS: For JSW in the medial compartment, the surface-fit method had lower within-participant interknee variability (σ(2)(within), 0.064; 95% CI, 0.04-0.09) compared with the midpoint method (σ(2)(within), 0.28; 95% CI, 0.20-0.43) and a higher ICC (0.93 vs 0.65; P < .001). Lateral JSW values were similar for the surface-fit method (σ(2)(within), 0.27; 95% CI, 0.18-0.43) and the midpoint method (σ(2)(within), 0.20; 95% CI, 0.14-0.31), with ICCs of 0.75 and 0.77, respectively (P = .80). With the surface-fit method, mean JSW measurements of the medial and lateral compartments of a control population were not significantly different from the contralateral uninjured knees of patients after ACL reconstruction. CONCLUSION: For measuring medial JSW, the surface-fit method was less variable across knees within a participant than the midpoint method, as evidenced by larger ICCs and lower interknee variability. For measuring lateral JSW, the 2 methods were similar. The JSW measurements of uninjured contralateral knees of patients with ACL reconstruction at 2 to 3 years postsurgery were not significantly different from those of a cohort of healthy control participants. Future work should be performed to demonstrate the validity of these methods for documenting change over time in the ACL-reconstructed knee.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。