Accuracy of Suture Passage During Arthroscopic Remplissage-What Anatomic Landmarks Can Improve It?: A Cadaveric Study

关节镜下填充术中缝线穿引的准确性——哪些解剖标志可以提高其准确性?:一项尸体研究

阅读:1

Abstract

BACKGROUND: Recent data suggest that inaccurate suture passage during remplissage may contribute to a loss of external rotation, with the potential to cause posterior shoulder pain because of the proximity to the musculotendinous junction. PURPOSE: To evaluate the accuracy of suture passage during remplissage and identify surface landmarks to improve accuracy. STUDY DESIGN: Descriptive laboratory study. METHODS: Arthroscopic remplissage was performed on 6 cadaveric shoulder specimens. Two single-loaded suture anchors were used for each remplissage. After suture passage, position was recorded in reference to the posterolateral acromion (PLA), with entry perpendicular to the humeral surface. After these measurements, the location of posterior cuff penetration was identified by careful surgical dissection. RESULTS: Twenty-four sutures were passed in 6 specimens: 6 sutures (25.0%) were correctly passed through the infraspinatus tendon, 12 (50%) were through the infraspinatus muscle or musculotendinous junction (MTJ), and 6 (25%) were through the teres minor. Suture passage through the infraspinatus were on average 25 ± 5.4 mm inferior to the PLA, while sutures passing through the teres minor were on average 35.8 ± 5.7 mm inferior to the PLA. There was an odds ratio of 25 (95% CI, 2.1-298.3; P < .001) that the suture would be through the infraspinatus if the passes were less than 3 cm inferior to the PLA. Sutures passing through muscle and the MTJ were significantly more medial than those passing through tendon, measuring on average 8.1 ± 5.1 mm lateral to the PLA compared with 14.5 ± 5.5 mm (P < .02). If suture passes were greater than 1 cm lateral to the PLA, it was significantly more likely to be in tendon (P = .013). CONCLUSION: We found remplissage suture passage was inaccurate, with only 25% of sutures penetrating the infraspinatus tendon. Passing sutures 1 cm lateral and within 3 cm inferior of the PLA improves the odds of successful infraspinatus tenodesis. We recommend this "safe zone" to improve the odds of infraspinatus tenodesis during remplissage. These results may help improve remplissage techniques and prevent previously reported complications, including external rotation loss and pain from myodesis.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。