Robotic-assisted gynecologic surgery associated tympanic membrane perforation: A report of two cases and review of the literature

机器人辅助妇科手术相关鼓膜穿孔:两例病例报告及文献复习

阅读:1

Abstract

Robotic gynecologic surgery is associated with the use of steep Trendelenburg positioning. Steep Trendelenburg is necessary to provide optimal exposure to the pelvis but is associated with an increased risk of non-surgical complications such as suboptimal ventilation, facial and laryngeal edema, increased intraocular and intracranial pressure as well as neurologic injury. Several case reports have described otorrhagia after robotic assisted surgery; however, there are limited reports on the risk of tympanic membrane perforation. To our knowledge, there are no published reports on tympanic membrane perforation in gynecologic nor gynecologic oncology surgery. We report two cases of perioperative tympanic membrane rupture and bloody otorrhagia associated with robot-assisted gynecologic surgery. In both cases otolaryngology/Ear Nose and Throat (ENT) was consulted, and the perforations resolved with conservative management.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。