Structure, Mechanics, and Instability of Fibrin Clot Infected with Staphylococcus epidermidis

表皮葡萄球菌感染的纤维蛋白凝块的结构、力学和不稳定性

阅读:9
作者:Tianhui Maria Ma, J Scott VanEpps, Michael J Solomon

Abstract

Health care-associated infection, over half of which can be attributed to indwelling medical devices, is a strong risk factor for thromboembolism. Although most experimental models of medical device infection draw upon isolated bacterial biofilms, in fact there is no infection without host protein contribution. Here we study, to our knowledge, a new model for medical device infection-that of an infected fibrin clot-and show that the common blood-borne pathogen Staphylococcus epidermidis influences this in vitro model of a blood clot mechanically and structurally on both microscopic and macroscopic scales. Bacteria present during clot formation produce a visibly disorganized microstructure that increases clot stiffness and triggers mechanical instability over time. Our results provide insight into the observed correlation between medical device infection and thromboembolism; the increase in model clot heterogeneity shows that S. epidermidis can rupture a fibrin clot. The resultant embolization of the infected clot can contribute to the systemic dissemination of the pathogen.