Importance Of Laboratory Detection Of Macro-Aspartate Aminotransferase

实验室检测大分子天冬氨酸氨基转移酶的重要性

阅读:1

Abstract

The macroenzyme form of aspartate aminotransferase (macro-AST) is formed by the binding of AST with immunoglobulins. Macro-AST excretion from serum is prolonged because of its high molecular weight, leading to increased AST activities. Because of the difficulty in detecting macro-AST through routine laboratory tests, affected patients often undergo repeated examinations, with associated anxiety. We report a case in which macro-AST was detected by assaying the patient's serum after refrigeration at 4ºC for 3 days. The sample showed progressive loss of AST activity compared with that frozen in the refrigerator, indicating the presence of macro-AST, which was confirmed as a complex with IgG-κ. The cold storage method was validated using many samples obtained from several patients. Use of this simple method to detect macro-AST may avoid unnecessary examinations and patient anxiety even at primary care facilities.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。