Could Novel Spinal Braces with Flexibility, Robotic Components, and Individualized Design Generate Sufficient Biomechanical Treatment Efficacy in Patients with Scoliosis?

具有灵活性、机器人组件和个性化设计的新型脊柱支具能否为脊柱侧弯患者带来足够的生物力学治疗效果?

阅读:1

Abstract

BACKGROUND: Patients with adolescent idiopathic scoliosis (AIS) require effective bracing to control curve progression. However, most traditional spinal braces commonly pose challenges in terms of undesired bulkiness and restricted mobility. Recent advancements have focused on innovative brace designs, utilizing novel materials and structural configurations to improve wearability and functionality. However, it remains unclear how effective these next-generation braces are biomechanically compared to traditional braces. OBJECTIVES: This review aimed to analyze the design features of next-generation AIS braces and assess their biomechanical effectiveness via reviewing contemporary studies. METHODS: Studies on newly designed scoliosis braces over the past decade were searched in databases, including Web of Science, PubMed, ScienceDirect, Wiley, EBCOHost and SpringerLink. The Joanna Briggs Institute Critical Appraisal Checklist for Cohort Studies was adopted to evaluate the quality of the included studies. The data extracted for biomechanical effect analysis included brace components/materials, design principle, interfacial pressure, morphological changes, and intercomparison parameters. RESULTS: A total of 19 studies encompassing 12 different kinds of braces met the inclusion/exclusion criteria. Clinical effectiveness was reported in 14 studies, with an average short-term Cobb angle correction of 25.4% (range: 12.41-34.3%) and long-term correction of 18.22% (range: 15.79-19.3%). This result aligned broadly with the previously reported efficacy of the traditional braces in short-term cases (range: 12.36-31.33%), but was lower than the long-term ones (range: 23.02-33.6%). Two included studies reported an interface pressure range between 6.0 kPa and 24.4 kPa for novel braces, which was comparable to that of the traditional braces (4.8-30.0 kPa). Additionally, five of six studies reported the trunk asymmetric parameters and demonstrated improvement in trunk alignment. CONCLUSIONS: This study demonstrates that most newly designed scoliosis braces could achieve comparable biomechanical efficacy to the conventional designs, particularly in interface pressure management and Cobb angle correction. However, future clinical adoption of these novel braces requires further improvements of ergonomic design and three-dimensional correction, as well as more investigation and rigorous evidence on the long-term treatment outcomes and cost-effectiveness.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。