Abstract
BACKGROUND: Surgical indication of ascending thoracic aortic aneurysms (ATAA) is generally performed in prevention. Guidelines use aortic diameter as a predictor of rupture and dissection; however, this single parameter alone has a limited value in predicting the real-world risk of acute aortic syndromes. The novel photon-counting CT scan(pc-CT) is capable of better-analyzing tissue composition and aortic characterization. The aim of the study is to assess whether the correlation between aortic wall thickness measured with a pc-CT scan and histology exists. METHODS: 14 Patients, with a mean age of 47 years, undergoing cardiac surgery for ATAA, who had preoperatively undergone a pc-CT scan, were retrospectively analyzed. Histology analyses of the resected aortic wall aneurysm were reviewed, and minimum/maximum measurements of intima+media of the aortic wall were performed. Radiology images were also examined, and aortic wall thickness measures were taken. Bland-Altman plots and Passing-Bablock regression analyses were conducted to evaluate the correlation between the values. RESULTS: pc-CT scan mean measurements were 1.05 and 1.69 mm, minimum/maximum, respectively. Mean minimum/maximum histology measurements were 1.66 and 2.82 mm, respectively. Bland Altman plots and Passing-Bablock regression analyses showed the absence of systematic bias and confirmed that measurement values were sufficiently similar (minimum -0.61 [CI 95% 0.16-1.38]; maximum -1.1 [0.73-2.99]). CONCLUSIONS: Despite results being merely preliminary, our study shows encouraging sufficiently similar results between aortic wall thickness measurements made with pc-CT scan and histology analyses.