Performance of Nuclear Magnetic Resonance-Based Estimated Glomerular Filtration Rate in a Real-World Setting

核磁共振估算肾小球滤过率在真实世界环境中的性能

阅读:1

Abstract

An accurate estimate of glomerular filtration rate (eGFR) is essential for proper clinical management, especially in patients with kidney dysfunction. This prospective observational study evaluated the real-world performance of the nuclear magnetic resonance (NMR)-based GFR(NMR) equation, which combines creatinine, cystatin C, valine, and myo-inositol with age and sex. We compared GFR(NMR) performance to that of the 2021 CKD-EPI creatinine and creatinine-cystatin C equations (CKD-EPI(2021Cr) and CKD-EPI(2021CrCys)), using 115 fresh routine samples of patients scheduled for urinary iothalamate clearance measurement (mGFR). Median bias to mGFR of the three eGFR equations was comparably low, ranging from 0.4 to 2.0 mL/min/1.73 m(2). GFR(NMR) outperformed the 2021 CKD-EPI equations in terms of precision (interquartile range to mGFR of 10.5 vs. 17.9 mL/min/1.73 m(2) for GFR(NMR) vs. CKD-EPI(2021CrCys); p = 0.01) and accuracy (P15, P20, and P30 of 66.1% vs. 48.7% [p = 0.007], 80.0% vs. 60.0% [p < 0.001] and 95.7% vs. 86.1% [p = 0.006], respectively, for GFR(NMR) vs. CKD-EPI(2021CrCys)). Clinical parameters such as etiology, comorbidities, or medications did not significantly alter the performance of the three eGFR equations. Altogether, this study confirmed the utility of GFR(NMR) for accurate GFR estimation, and its potential value in routine clinical practice for improved medical care.