OBJECTIVE: it was to evaluate the efficacy and safety of rapamycin-eluting stents at different doses in the treatment of coronary artery narrowing in miniature pigs. METHODS: a total of 20 miniature pigs were randomly assigned into four groups: S1 group (low-dose rapamycin-coated stent, 55 µg/mm(2)), S2 group (medium-dose rapamycin-coated stent, 120 µg/mm(2)), S3 group (high-dose rapamycin-coated stent, 415 µg/mm(2)), and D0 group (bare metal stent). The stent size was 3.0 mm × 18 mm, with an over-expansion ratio of 1.1. Each group consisted of five pigs. Stent implantation was followed by euthanasia and tissue collection after 1 month. Vascular measurements, inflammatory response scores, cardiovascular injury scores, endothelialization scores, liver and kidney function indices, and myocardial injury markers were compared among the groups. RESULTS: the neointimal thickness in the S2 and S3 groups was significantly lower than that in the S1 and D0 groups (S1 group: 24.08 ± 3.95, S2 group: 1.86 ± 0.28, S3 group: 2.72 ± 0.74, D0 group: 22.85 ± 3.15, P < 0.05). The residual lumen area in the S2 and S3 groups was significantly larger than that in the S1 and D0 groups (S1 group: 2.73 ± 0.51, S2 group: 4.25 ± 0.78, S3 group: 3.91 ± 0.73, D0 group: 2.91 ± 0.44, P < 0.05). The neointimal area in the S2 and S3 groups was significantly smaller than that in the S1 and D0 groups (S1 group: 3.44 ± 0.84, S2 group: 1.78 ± 0.25, S3 group: 2.07 ± 0.41, D0 group: 3.43 ± 0.72, P < 0.05). The degree of lumen narrowing in the S2 and S3 groups was significantly lower than that in the S1 and D0 groups (S1 group: 44.25 ± 3.66%, S2 group: 14.19 ± 2.01%, S3 group: 15.29 ± 2.45%, D0 group: 21.79 ± 3.51%, P < 0.05). The inflammation scores of coronary artery walls in the S2 and S3 groups of miniature pigs were markedly lower than those in the S1 and D0 groups (P < 0.05). The cardiovascular injury scores (P = 0.072) and endothelialization scores (P = 0.085) differed slightly among the four groups (P > 0.05). Post-operative liver function indicators (alanine transaminase, aspartate transaminase), kidney function indicators (blood urea nitrogen, serum creatinine), and myocardial injury markers (creatine kinase, creatine kinase-MB) also showed neglectable differences among the four groups (P > 0.05). CONCLUSION: medium and high doses of rapamycin-eluting stents effectively inhibit neointimal hyperplasia and local vascular inflammatory response in miniature pigs without causing damage to liver and kidney functions or myocardial cells. These stents demonstrate high efficacy and safety. Rapamycin-coated coronary stents, as an effective treatment for coronary artery stenosis, may achieve further improvement in therapeutic efficacy through optimization of drug dosage and stent design.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。