Clinical application of CT-assisted body surface localization combined with intraoperative stereotactic anatomical localization in thoracoscopic lung nodule resection: a single-centre retrospective study

CT辅助体表定位联合术中立体定向解剖定位在胸腔镜肺结节切除术中的临床应用:单中心回顾性研究

阅读:1

Abstract

BACKGROUND: Today, the detection rate of lung nodules is increasing. Some of these nodules may become malignant. Thus, timely resection of potentially malignant nodules is essential. However, Identifying the location of nonsurface or soft-textured nodules during surgery is challenging. Various localization techniques have been developed to accurately identify lung nodules. Common methods include preoperative CT-guided percutaneous placement of hook wires and microcoils. Nonetheless, these procedures may cause complications such as pneumothorax and haemothorax. Other methods regarding localization of pulmonary nodules have their own drawbacks. We conducted a clinical study which was retrospective to identify a safe, accurate and suitable method for determining lung nodule localization. To evaluate the clinical value of CT-assisted body surface localization combined with intraoperative stereotactic anatomical localization in thoracoscopic lung nodule resection. METHODS: We retrospectively collected the clinical data of 120 patients who underwent lung nodule localization and resection surgery at the Department of Thoracic Surgery, First Affiliated Hospital of Bengbu Medical College, from January 2020 to January 2022. Among them, 30 patients underwent CT-assisted body surface localization combined with intraoperative stereotactic anatomical localization, 30 patients underwent only CT-assisted body surface localization, 30 patients underwent only intraoperative stereotactic anatomical localization, and 30 patients underwent CT-guided percutaneous microcoil localization. The success rates, complication rates, and localization times of the four lung nodule localization methods were statistically analysed. RESULTS: The success rates of CT-assisted body surface localization combined with intraoperative stereotactic anatomical localization and CT-guided percutaneous microcoil localization were both 96.7%, which were significantly higher than the 70.0% success rate in the CT-assisted body surface localization group (P < 0.05). The complication rate in the combined group was 0%, which was significantly lower than the 60% in the microcoil localization group (P < 0.05). The localization time for the combined group was 17.73 ± 2.52 min, which was significantly less than that (27.27 ± 7.61 min) for the microcoil localization group (P < 0.05). CONCLUSIONS: CT-assisted body surface localization combined with intraoperative stereotactic anatomical localization is a safe, painless, accurate, and reliable method for lung nodule localization.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。