Left ventricular unloading therapy using Impella 5.5 after emergency surgery for acute myocardial infarction mechanical complication: a case report

急性心肌梗死机械并发症急诊手术后采用 Impella 5.5 进行左心室卸载治疗:病例报告

阅读:1

Abstract

BACKGROUND: Following an acute myocardial infarction (AMI), surgery for left ventricular free wall rupture (LVFWR) and ventricular septal rupture (VSR) has a high in-hospital mortality rate, which has not improved significantly over time. Unloading the LV is critical to preventing excessive stress on the repair site and avoiding problems such as bleeding, leaks, patch dehiscence, and recurrence of LVFWR and VSR because the tissue is so fragile. We present two cases of patients who used Impella 5.5 for LV unloading following emergency surgery for AMI mechanical complications. CASE PRESENTATION: A 76-year-old male STEMI patient underwent fibrinolysis of the distal right coronary artery. Three days later, he passed out and went into shock. Echocardiography revealed a cardiac tamponade. We found an oozing-type LVFWR on the posterolateral wall and treated it with a non-suture technique using TachoSil. Before the patient was taken off CPB, Impella 5.5 was inserted into the LV via a 10 mm synthetic graft connected to the right axillary artery. We kept the flow rate above 4.0 to 4.5 L/min until POD 3 to reduce LV wall tension while minimizing pulsatility. On POD 6, we weaned the patient from Impella 5.5. A postoperative cardiac CT scan showed no contrast leakage from the LV. However, a cerebral hemorrhage on POD 4 during heparin administration complicated his hospitalization. Case 2: A diagnosis of cardiogenic shock caused by STEMI occurred in an 84-year-old male patient, who underwent PCI of the LAD with IABP support. Three days after PCI, echocardiography revealed VSR, and the patient underwent emergency VSR repair with two separate patches and BioGlue applied to the suture line between them. Before weaning from CPB, we implanted Impella 5.5 in the LV and added venoarterial extracorporeal membrane oxygenation (VA-ECMO) support for right heart failure. The postoperative echocardiography revealed no residual shunt. CONCLUSIONS: Patients undergoing emergency surgery for mechanical complications of AMI may find Impella 5.5 to be an effective tool for LV unloading. The use of VA-ECMO in conjunction with Impella may be an effective strategy for managing VSR associated with concurrent right-sided heart failure.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。