Donor neo-atrial cuff construction after accidental lower lobe vein transection

意外下叶静脉横断后重建供体新心房袖套

阅读:1

Abstract

BACKGROUND: An inadequate donor left atrial cuff is a rare technical issue after graft procurement for lung transplantation. With regard to the shortage of suitable donor organs for lung transplantation, these organs should be surgically reconstructed to avoid the loss of an organ and a futile intervention in the critically ill recipient. CASE PRESENTATION: We report a case of a 62-year old patient who underwent bilateral sequential lung transplantation for chronic obstructive pulmonary disease. During isolated lung procurement, the right inferior pulmonary vein was circumferentially transsected and separated from the right superior pulmonary and middle lobe veins. Subsequently, a reconstruction of the left atrial cuff with an acellular biological patch was performed to complete the atrium anastomosis. The patient experienced an uneventful postoperative recovery and a follow-up ventilation/perfusion scan showed normal perfusion of the right lower lobe. CONCLUSIONS: This case demonstrates that reconstruction of an inadequate left atrial cuff with a biological patch is feasible and allows for an adequate venous drainage and therefore normal transplant organ function.