Minimally invasive closure of transthoracic ventricular septal defect: postoperative complications and risk factors

经胸微创室间隔缺损修补术:术后并发症和危险因素

阅读:2

Abstract

OBJECTIVES: To summarize and analyze the clinical characteristics of postoperative complications after minimally invasive closure of transthoracic ventricular septal defect, and to explore the risk factors for its occurrence. METHODS: Retrospectively analyzed the clinical data of 209 patients underwent transthoracic ventricular septal defect closure performed in the Department of Cardiothoracic Surgery, Children's Hospital of Chongqing Medical University from January 2018 to January 2020, obtained relevant clinical data from the electronic medical record system and summarized their postoperative complications. And used univariate logistics regression and multivariate logistics regression to analyze the risk factors of its occurrence. RESULTS: The postoperative hospital stay of 27 patients was longer than 9 days. Residual shunt occurred in 33 patients recently after operation. One patient underwent surgical treatment again because of mechanical hemolysis after the operation. Two patients were re-operated 1 month and 10 months after surgery because of persistent moderate to severe aortic regurgitation. After surgery, 3 patients underwent pericardiocentesis due to a large amount of pericardial effusion, and 2 patients developed a new atrioventricular block after the operation. No other serious adverse events occurred. Multivariate logistic regression analysis showed that the size of VSD defect (OR: 1.494, 95% Cl: 1.108-2.013, P value: 0.008) was related to long postoperative hospitalization. The residual shunt is related to the size of the occluder (OR: 1.452, 95%Cl: 1.164-1.810, P value: 0.001). In the univariate logistics regression analysis, no risk factors related to serious adverse events were found. CONCLUSIONS: The minimally invasive closure of transthoracic ventricular septal defect is very effective, with no mortality and low incidence of serious adverse events after surgery. The size of the defect is related to the long postoperative hospitalization, and the size of the occluder is related to the residual shunt in the early postoperative period. No risk factors related to the occurrence of serious adverse events after the operation were found.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。