Clinical evaluation of percutaneous and intra-operative device closure of atrial septal defects under transesophageal echocardiographic guidance: one center experience and mid-term follow-up

经食道超声心动图引导下经皮和术中装置封堵房间隔缺损的临床评价:单中心经验和中期随访

阅读:1

Abstract

OBJECTIVE: The percutaneous closure of a single secundum atrial septal defect (ASD) under transesophageal echocardiography guidance as an accepted alternative to the transcatheter closure with fluoroscopy has been proven. However, the technique has not been routinely used. This study was to present and share our experience in comparing the clinical outcomes of the percutaneous and intra-operative device closure (IODC) of atrial septal defects without fluoroscopy. METHODS: From January 2013 to December 2016, 103 patients with maximum diameters of ASD of less than 30 mm were allocated to groups taking either the percutaneous closure of atrial septal defects approach (PASD group, n = 53) or the intra-operative device closure approach (IODC Group, n = 50). They were operated on using the minimally invasive Amplatzer duct occluder under the guidance of transesophageal echocardiography without cardiopulmonary bypass. Echocardiography was performed to obtain an en face view of the ASD and important surrounding structures before the operation. Patient characteristics, perioperative data, and follow-up data were retrospectively documented and analyzed. RESULTS: Patient characteristics were comparable between the two groups. These were no differences in the maximum diameters of defects and the size of the occluders in each group (16.4 ± 5.3 mm vs16.4 ± 5.2 mm, P = 0.98; 22.4 ± 5.8 mm vs 21.3 ± 6.6 mm, P = 0.38). Intracardiac manipulation time was 20.72 ± 7.70 min in the PASD group and 6.01 ± 1.03 min in the IODC group (P < 0.001). The procedure time was 28.70 ± 10.41 min in the PASD group and 39.13 ± 6.03 min in the IODC group (P < 0.001). The successful closure defect was 100% in both groups when the maximum diameter of defect less than 25 mm. Four patients the PASD groups with maximum diameters between 25 mm and 30 mm were transferred to the IOCD group after unsuccessful device implantations. The total occlusion rate was 82% immediately after deployment, 98% at 3 months, and 100% at 6 months. No cardiac-related complications occurred during the follow-up period of between 3 to 65 months (mean 21.4 ± 9.8 months). CONCLUSIONS: Percutaneous device closures of Secundum atrial septal defects showed safety and high efficiency in patients under guidance by transesophageal echocardiography when compared with intra-operative device closures and are especially suited for women and children.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。