Prospective, randomized, single blinded pilot study of a new FlatWire based sternal closure system

一项前瞻性、随机、单盲试点研究,旨在评估一种新型基于扁平钢丝的胸骨闭合系统。

阅读:1

Abstract

BACKGROUND: Unstable steel wire cerclage following open heart surgery may result in increased pain, sternal cut-through, non-union, or dehiscence. These complications lead to longer hospital stays, increased cost, higher morbidity, and patient dissatisfaction. The Figure 8 FlatWire Sternal Closure System is a new construct which is a simple, intuitive, and inexpensive alternative for primary sternal repair following open heart surgery. Prior bench-top testing of FlatWire has demonstrated superior strength and stiffness compared to traditional steel wire. We present our initial experience in a prospective, randomized, single blinded pilot study utilizing this FDA approved system. METHODS: Sixty-three patients undergoing elective complete sternotomies at a single institution were randomly assigned to receive either the Figure 8 FlatWire or standard steel wire cerclage. All surgeries were performed by a single board certified cardiothoracic surgeon. Data collected included: Age, BMI, pump time, off pump to surgical stop time, length of hospital stay after surgery, cost from time of surgery to discharge, and pain on a visual analog pain scale on the day of discharge, day 30, and day 60. RESULTS: The groups were well matched. Patients receiving the Figure 8 FlatWire (33) had a reduction in length of stay compared to patients receiving steel wire circlage (30), but it was not statistically significant (6.8 vs. 7.8 days respectively, p < 0.093). Additionally those with the FlatWire reported significantly decreased pain at day of discharge (3.07 vs. 4.92 points on pain scale, p < 0.0066), with similar pain scores at 30 and 60 days. Off pump to surgery stop time was increased by 15.9 minutes in patients receiving the FlatWire vs. steel wires (55.7 vs. 71.6 minutes, p = 0.00025). Mean cost from surgery until discharge was $87,820.98 in the FlatWire group vs. $91,930.29 in the steel wire group (p < 0.3082). CONCLUSION: Early clinical results suggest that Figure 8 FlatWire provides excellent stability, which resulted in significantly diminished postoperative pain at discharge. Although not significant there was a trend toward decreased length of stay, and reduced cost. Further clinical research is warranted to expand upon these initial trends and validate long term outcomes.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。