Impact of epicardial ablation of concomitant atrial fibrillation on atrial natriuretic peptide levels and atrial function in 6 months follow-up: does preoperative ANP level predict outcome of ablation?

心外膜消融治疗伴发心房颤动对 6 个月随访中心房利钠肽水平和心房功能的影响:术前 ANP 水平能否预测消融结果?

阅读:1

Abstract

BACKGROUND: Epicardial ablation concomitant to cardiac surgery is an easy and safe approach to treat atrial fibrillation (AF), but its efficacy in longstanding persistent (LsPe) AF remains intermediate. Although larger left atrial size has been associated with worse outcome after ablation, biochemical predictors of success are not well established. The aim of this study was to evaluate relationship between biochemical marker, echo-characteristic and cardiac rhythm in 6 months follow-up after epicardial ultrasound (HIFU) ablation. METHODS: We included 78 consecutive patients, who underwent elective cardiac surgery. 42 patients with AF (11.9% paroxysmal, 23.8% persistent, 64.3% LsPeAF) underwent concomitant HIFU ablation (AF ablation group), 16 with AF underwent cardiac surgery without ablation (AF control) and 20 had preoperatively normal sinus rhythm (SR control). We measured plasma ANP secretion before, on postoperative day (POD) 1, POD 7 as well as 3 and 6 months after surgery. Moreover, we estimated cardiac rhythm and atrial mechanical function by Atrial Filling Fraction (AFF) and A-wave velocity in follow-up. RESULTS: Baseline ANP levels were higher in patients with LsPeAF, as compared to the paroxysmal and permanent AF and to the SR control group. Patients with LsPeAF (n = 27) who converted to SR had preoperatively smaller left atrial diameter (LAD) and LA area (p < 0.05) and higher ANP level (p = 0.009) than those who remained in AF at 6 months after ablation. Multivariate regression analysis revealed that only preoperative ANP level was an independent predictor of cardiac rhythm after ablation. Patients with LsPeAF and preoperative ANP >7.5 nmol/l presented with SR in 80%, in contrast to those with ANP <7.5 nmol/l who converted to SR in 20%. We detected gradual increase of AFF and A-velocity at 6 months after ablation (p < 0.05) solely in AF ablation group. ANP levels were increased on POD 1 in ablation group (p < 0.05), without changes in further follow-up. CONCLUSION: Our results indicate that preoperative ANP levels may be a new biochemical predictor of successful epicardial ablation in patients with concomitant LsPeAF. HIFU ablation caused a significant improvement of atrial mechanical function and gradual increase of AFF and did not associate with alteration of atrial endocrine secretion at 6 months follow-up.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。