BACKGROUND: Endotracheal tube (ETT) designs to decrease the risk of ventilator associated pneumonia (VAP) include supraglottic suctioning, and/or modifications of the cuff shape. The TaperGuard™ ETT has a tapered, polyvinylchloride cuff designed to reduce microaspiration around channels that form with a standard barrel-shaped cuff. We compared risk of postoperative pneumonia using the TaperGuard™ ETT and the standard ETT in surgical patients requiring general anesthesia with endotracheal intubation. METHODS: We used an interrupted time-series design to compare endotracheal intubation using the TaperGuard™ ETT (intervention cohort), and a historic cohort using the standard ETT (baseline cohort), among surgical patients requiring hospital admission. We compared the incidence of postoperative pneumonia in the intervention and baseline cohorts. Data were collected from the electronic health record and linked to patient-level data from National Surgical Quality Improvement Project. Additionally, we performed secondary analyses in a subgroup of patients at high risk of postoperative pneumonia. RESULTS: 15,388 subjects were included; 6351 in the intervention cohort and 9037 in the baseline cohort. There was no significant difference in the incidence of postoperative pneumonia between the intervention cohort (1.62%) and the baseline cohort (1.79%). The unadjusted odds ratio (OR) of postoperative pneumonia was 0.90 (95% CI: 0.70, 1.16; p = 0.423) and the OR adjusted for patient characteristics and potential confounders was 0.90 (95% CI: 0.69, 1.19; p = 0.469), comparing the intervention and baseline cohorts. There was no a priori selected subgroup of patients for whom the use of the TaperGuard™ ETT was associated with decreased odds of postoperative pneumonia relative to the standard ETT. Hospital mortality was higher in the intervention cohort (1.5%) compared with the baseline cohort (1.0%; OR 1.46, 95% CI: 1.09, 1.95; p = 0.010). CONCLUSIONS: The broad implementation of the use of the TaperGuard™ ETT for intubation of surgical patients was not associated with a reduction in the risk of postoperative pneumonia. In the setting of a low underlying postoperative pneumonia risk and the use of recommended preventative VAP bundles, further risk reduction may not be achievable by simply modifying the ETT cuff design in unselected or high-risk populations undergoing inpatient surgery. TRIAL REGISTRATION: ClinicalTrials.gov, ID NCT02450929 .

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。