Application of intraoperative lung-protective ventilation varies in accordance with the knowledge of anaesthesiologists: a single-Centre questionnaire study and a retrospective observational study

术中肺保护性通气的应用情况因麻醉医师的知识水平而异:一项单中心问卷调查研究和一项回顾性观察研究证实了这一点。

阅读:1

Abstract

BACKGROUND: The benefits of lung-protective ventilation (LPV) with a low tidal volume (6 mL/kg of ideal body weight [IBW]), limited plateau pressure (< 28-30 cm H(2)O), and appropriate positive end-expiratory pressure (PEEP) in patients with acute respiratory distress syndrome have become apparent and it is now widely adopted in intensive care units. Recently evidence for LPV in general anaesthesia has been accumulated, but it is not yet generally applied by anaesthesiologists in the operating room. METHODS: This study investigated the perception about intraoperative LPV among 82 anaesthesiologists through a questionnaire survey and identified the differences in ventilator settings according to recognition of lung-protective ventilation. Furthermore, we investigated the changes in the trend for using this form of ventilation during general anaesthesia in the past 10 years. RESULTS: Anaesthesiologists who had received training in LPV were more knowledgeable about this approach. Anaesthesiologists with knowledge of the concept behind LPV strategies applied a lower tidal volume (median (IQR [range]), 8.2 (8.0-9.2 [7.1-10.3]) vs. 9.2 (9.1-10.1 [7.6-10.1]) mL/kg; p = 0.033) and used PEEP more frequently (69/72 [95.8%] vs. 5/8 [62.5%]; p = 0.012; odds ratio, 13.8 [2.19-86.9]) for laparoscopic surgery than did those without such knowledge. Anaesthesiologists who were able to answer a question related to LPV correctly (respondents who chose 'height' to a multiple choice question asking what variables should be considered most important in the initial setting of tidal volume) applied a lower tidal volume in cases of laparoscopic surgery and obese patients. There was an increase in the number of patients receiving LPV (V(T) < 10 mL/kgIBW and PEEP ≥5 cm H(2)O) between 2004 and 2014 (0/818 [0.0%] vs. 280/818 [34.2%]; p <  0.001). CONCLUSIONS: Our study suggests that the knowledge of LPV is directly related to its implementation, and can explain the increase in LPV use in general anaesthesia. Further studies should assess the impact of using intraoperative LPV on clinical outcomes and should determine the efficacy of education on intraoperative LPV implementation.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。