K-Y™ jelly inhibits increase in endotracheal tube cuff pressure during nitrous oxide exposure in vitro

KY™凝胶在体外实验中可抑制一氧化二氮暴露期间气管插管套囊压力的升高。

阅读:1

Abstract

BACKGROUND: The increase in endotracheal tube cuff pressure due to nitrous oxide diffusion is a well-known risk during general anesthesia using nitrous oxide. We hypothesized that lubricating endotracheal tube cuffs with K-Y™ Jelly might inhibit the increase in cuff pressure that occurs during exposure to nitrous oxide. METHODS: We used two types of endotracheal tube cuffs: one made from ultrathin polyurethane (PU) and another made from conventional polyvinyl chloride (PVC). Using a pediatric trachea model, which consisted of an acrylic cylinder with an internal diameter of 12 mm, we measured changes in the cuff pressure during nitrous oxide exposure in size 5.0-mm internal diameter endotracheal tubes with each type of cuff, with and without lubrication with K-Y™ Jelly. RESULTS: During nitrous oxide exposure, the increase in cuff pressure was significantly lower in the lubricated cuffs than in the non-lubricated cuffs in both types of cuffs (PVC, P < 0.0001; PU, P < 0.0001). However, the cuff compliance in the trachea model was unaffected by lubrication in both types of cuffs. CONCLUSIONS: Lubrication of endotracheal tube cuffs with K-Y™ Jelly may effectively delay the increase in cuff pressure that occurs during general anesthesia using nitrous oxide.