Comparison of the trapezius and the adductor pollicis muscle as predictor of good intubating conditions: a randomized controlled trial

斜方肌和拇内收肌作为良好插管条件预测指标的比较:一项随机对照试验

阅读:1

Abstract

BACKGROUND: Adequate muscle relaxation is important for ensuring optimal conditions for intubation. Although acceleromyography of the adductor pollicis muscle is commonly used to assess conditions for intubation, we hypothesized that acceleromyography of the trapezius is more indicative of optimal intubating conditions. The primary outcome was the difference between both measurement sites with regard to prediction of good or acceptable intubating conditions. METHODS: Neuromuscular blockade after injection of rocuronium 0.3 mg/kg IV was measured simultaneously with acceleromyography of the adductor pollicis muscle and the trapezius muscle in sixty female patients, American Society of Anesthesiologists physical status I to III, undergoing general anesthesia for gynecologic surgery. Exclusion criteria were: expected difficult tracheal intubation (e.g. history of difficult intubation, reduced mouth opening (< 2 cm) and/or Mallampati Score 4), increased risk of pulmonary aspiration (e.g. gastroesophageal reflux or delayed gastric emptying) allergies to drugs used during the study, pregnancy, neuromuscular diseases, medication with potential to influence neuromuscular function (e.g. furosemide, magnesium, cephalosporins) and hepatic or renal insufficiency (serum bilirubin >26 μmol/L, serum creatinine >90 μmol/l). Patients were randomized to 2 groups: group A (n = 30): endotracheal intubation after onset of the neuromuscular block at the adductor pollicis muscle. Group B (n = 30): endotracheal intubation after onset at the trapezius muscle. Intubating conditions were compared between both groups by means of a standardised score (the Copenhagen score) with Fisher's exact test. RESULTS: Onset of the block after rocuronium injection was observed at the adductor pollicis muscle compared to the trapezius with 2.8 (1.1) versus 2.5 (1.1) min (mean ± SD; P = 0.006). Intubating conditions were poor in 2 patients (7%) of group A, and in 1 patient (3%) of group T. They were acceptable (either excellent or good) in 28 patients (93%) in group A, and in 1 patient (97%) in group T (P = 0.82). CONCLUSIONS: Performing acceleromyography at the trapezius muscle reduced the time between injection of neuromuscular blocking agents and intubation by 18 s (11%). Thus, trapezius muscle acceleromyography is an acceptable alternative to adductor pollicis muscle acceleromyography in predicting acceptable intubating conditions, which allows for earlier indication of adequate intubating conditions. TRIAL REGISTRATION: ClinicalTrial.gov Identifier: NCT01849198 . Registered April 29, 2013.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。