Displacement of the full body of a dental implant into the sinus space without membrane perforation and subsequent osseointegration: a case report

牙种植体整体移位至鼻窦腔内,未造成膜穿孔,并最终实现骨整合:病例报告

阅读:1

Abstract

An increasing number of studies have investigated the use of osteotome sinus floor elevation (OSFE) with simultaneous implant placement for maxillary sinus floor residual bone height (RBH) <4 mm. Many studies have reported good clinical results, but very few have reported complications related to this procedure. Here, the case of a 50-year-old female patient with an RBH in the left upper posterior region of 1-4 mm, who underwent OSFE with simultaneous placement of three Bicon short® implants, is described. One of the implants was found to be displaced during the second-stage surgery. The displaced implant was removed using piezosurgery, OSFE with simultaneous implant placement was repeated, and the missing tooth was reconstructed 6 months later. This case suggests that OSFE with simultaneous implant placement is feasible for severely atrophic maxillary sinus floor, but carries a risk of implant displacement.