Effect of factors on the space between the posterior capsule and IOL

影响后囊膜与人工晶状体之间间隙的因素

阅读:2

Abstract

OBJECTIVES: To evaluate the effect of factors on the space between the posterior capsule and IOL. METHODS: A total of 126 patients were included in the study. All patients underwent AS-OCT examinations after surgery. The relationship between the posterior capsule-IOL (PC-IOL) adhesion range and various factors, including IOL type, follow-up period, axial length, and lens thickness, were analyzed. RESULTS: When the follow-up period was shorter than 1 week, the proportion of PC-IOL adhesion range greater than 1/2 in the ZA9003, softec, SN6ATX, and 525 groups was 66.7%, 78.9%, 25%, and 53.8%, respectively. When the follow-up period was longer than 1 month, these proportions increased to 75%, 100%, 40.8%, and 100%, respectively. In the multivariate logistic regression analysis, only the IOL types and follow-up period were statistically significant, while axial length and lens thickness were not statistically significant. CONCLUSION: The follow-up period and IOL types affect the space between the IOL and the posterior capsule, whereas axial length and lens thickness do not. Among the four IOL types studied, the softec IOL has the strongest adhesive power, while the SN6ATX IOL has the weakest.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。