A feasibility study for objective evaluation of visual acuity based on pattern-reversal visual evoked potentials and other related visual parameters with machine learning algorithm

基于模式反转视觉诱发电位及其他相关视觉参数,并结合机器学习算法对视力进行客观评价的可行性研究

阅读:1

Abstract

BACKGROUND: To develop machine learning models for objectively evaluating visual acuity (VA) based on pattern-reversal visual evoked potentials (PRVEPs) and other related visual parameters. METHODS: Twenty-four volunteers were recruited and forty-eight eyes were divided into four groups of 1.0, 0.8, 0.6, and 0.4 (decimal vision). The relationship between VA, peak time, or amplitude of P100 recorded at 5.7°, 2.6°, 1°, 34', 15', and 7' check sizes were analyzed using repeated-measures analysis of variance. Correlations between VA and P100, contrast sensitivity (CS), refractive error, wavefront aberrations, and visual field were analyzed by rank correlation. Based on meaningful P100 peak time, P100 amplitude, and other related visual parameters, four machine learning algorithms and an ensemble classification algorithm were used to construct objective assessment models for VA. Receiver operating characteristic (ROC) curves were used to compare the efficacy of different models by repeated sampling comparisons and ten-fold cross-validation. RESULTS: The main effects of P100 peak time and amplitude between different VA and check sizes were statistically significant (all P < 0.05). Except amplitude at 2.6° and 5.7°, VA was negatively correlated with peak time and positively correlated with amplitude. The peak time initially shortened with increasing check size and gradually lengthened after the minimum value was reached at 1°. At the 1° check size, there were statistically significant differences when comparing the peak times between the vision groups with each other (all P < 0.05), and the amplitudes of the vision reduction groups were significantly lower than that of the 1.0 vision group (all P < 0.01). The correlations between peak time, amplitude, and visual acuity were all highest at 1° (r(s) = - 0.740, 0.438). VA positively correlated with CS and spherical equivalent (all P < 0.001). There was a negative correlation between VA and coma aberrations (P < 0.05). For different binarization classifications of VA, the classifier models with the best assessment efficacy all had the mean area under the ROC curves (AUC) above 0.95 for 500 replicate samples and above 0.84 for ten-fold cross-validation. CONCLUSIONS: Machine learning models established by meaning visual parameters related to visual acuity can assist in the objective evaluation of VA.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。