Modified suture-assisted canaloplasty in Asians with primary open-angle glaucoma: a prospective study with 12-month follow-up

改良缝合辅助小梁成形术治疗亚洲原发性开角型青光眼:一项为期12个月的前瞻性研究

阅读:1

Abstract

BACKGROUND: To evaluate the efficacy and safety of modified suture-assisted canaloplasty in Asians with primary open-angle glaucoma (POAG). METHODS: A prospective, consecutive cases study, evaluating a modified canaloplasty by twisted 6/0 suture was performed on Asian POAG patients. Three modifications of this canaloplasty included opening the Schlemm's canal by viscocanalostomy, circumferential probing by a twisted 6/0 suture and loose suture of the superficial scleral flap. The twisted 6/0 suture was selected as a prober based on characteristical analysis of size and contact measurement as well as chemical composition conducted among 5/0, twisted 6/0 polypropylene sutures and the microcatheter. Success criteria were defined as intraocular pressure (IOP) ≤ 21 mmHg, 18 mmHg, 15 mmHg, and ≥ 20% reduction without (complete success) or with medications (qualified success). Efficacy was assessed by the success rate of circumferential catheterization, IOP values, the success rate of the surgery, the number of IOP-lowering medications, best-corrected vision acuity (BCVA), cup-to-disc ratio (C/D), and mean deviation (MD). Safety was evaluated by adverse events. RESULTS: Forty eyes from 40 consecutive patients were included with a mean follow-up of 14.8 ± 3.0 months. Circumferential catheterization was successfully conducted in 36 eyes (90%). Mean IOP decreased from 26.2 ± 6.9 mmHg to 14.5 ± 2.7 mmHg at 12 months postoperatively. While medication numbers were reduced from 3.2 ± 0.6 to 0.5 ± 0.8 at month 12 (both p < 0.001). Qualified success rate was 97.2% [95% confidence interval (CI) 0.92-1.03], 86.1% (95% CI 0.74-0.98) and 66.7% (95% CI 0.51-0.83) at 12 months with three criteria. BCVA, C/D and MD did not show progression at 1-year follow-up (p > 0.05). Age, baseline IOP, and spherical equivalent negatively influenced the success rate significantly (all p < 0.05). Adverse events included hyphema (30.6%), IOP spike > 25 mmHg (8.3%), and peripheral synechia to the trabecular-Descemet's membrane (2.7%). CONCLUSION: Twisted 6/0 suture can be an ideal material for cannulation. Modified suture-assisted canaloplasty is an effective, safe alternative with a cost-efficient feature for patients with POAG, especially in developing countries. TRIAL REGISTRATION: This trial was registered in the Chinese Clinical Trial Registry ( ChiCTR1900028618 , 29/12/2019).

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。