A novel surgical technique for prevention of Ahmed glaucoma valve tube exposure: long scleral flap augmented with Tenon advancement and duplication

一种预防Ahmed青光眼引流阀暴露的新型手术技术:采用Tenon氏囊前移和重复缝合技术增强长巩膜瓣。

阅读:1

Abstract

BACKGROUND: To describe a new technique and present its long-term outcome for prevention of Ahmed glaucoma valve (AGV) tube exposure in patients with refractory glaucoma. METHODS: Twenty-seven eyes of 24 patients (mean age, 50 years; age range, 16-78 years; 8 females, 16 males) with refractory glaucoma who had the AGV implant were retrospectively reviewed. For AGV implantation, a long scleral flap combined with Tenon advancement and duplication was used. In this technique, a long scleral flap is created to completely cover the extraocular part of valve's tube, and the flap surface is covered with duplicated Tenon's tissue. The average follow-up after AGV implantation was 21.7 months (range, 12-36 months). RESULTS: The mean intraocular pressure before the operation, which was 44.1 mmHg (range, 26-62 mmHg), decreased to 14.2 mmHg (range, 8-20 mmHg) at the last follow-up visit, showing 67% reduction with AGV implantation. The mean number of antiglaucomatous medications was 4.1 before the AGV implantation and decreased to 0.9 after the operation, showing 88% reduction. In 14 eyes (51.9%), there was no change in the best corrected visual acuity (BCVA), and in 11 eyes (40.7%), the BCVA increased by 2 lines on the Snellen chart postoperatively. No patient developed postoperative hypotony, flat anterior chamber, diplopia, strabismus, erosion or exposure of the tube, or tube/plate migration. CONCLUSIONS: The long scleral flap augmented with Tenon advancement and duplication is an effective and safe surgical technique for the implantation of AGV and preventing tube exposure in cases of refractory glaucoma.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。