Ultrasound quantification of pleural effusion volume in supine position: comparison of three model formulae

仰卧位胸腔积液量的超声定量:三种模型公式的比较

阅读:1

Abstract

BACKGROUND: To investigate the accuracy of three model formulae for ultrasound quantification of pleural effusion (PE) volume in patients in supine position. METHODS: A prospective study including 100 patients with thoracentesis and drainage of PE was conducted. Three model formulae (single section model, two section model and multi-section model) were used to calculate the PE volume. The correlation and consistency analyses between calculated volumes derived from three models and actual PE volume were performed. RESULTS: PE volumes calculated by three models all showed significant linear correlations with actual PE volume in supine position (all p < 0.001). The reliability of multi-section model in predicting PE volume was significantly higher than that of single section model and slightly higher than that of two section model. When compared with actual drainage volume, the intra-class correlation coefficients (ICCs) of single section model, two section model and multi-section model were 0.72, 0.97 and 0.99, respectively. Significant consistency between calculated PE volumes by using two section model and multi-section model existed for full PE volume range (ICC 0.98). CONCLUSION: Based on the convenience and accuracy of ultrasound quantification of PE volume, two section model is recommended for pleural effusion assessment in routine clinic, though different model formulae can be selected according to clinical needs.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。