Tracheal airway pressure in tracheostomy tube capping trials: an experimental study

气管切开术插管封堵试验中的气管气道压力:一项实验研究

阅读:1

Abstract

BACKGROUND: Tracheostomy tube capping is a commonly used test to determine if the tracheostomy tube can be removed. The success of the capping trial depends on the patient's ability to maintain sufficient spontaneous breathing with an occluded tracheostomy tube. The impact of an occluded tracheotomy tube on airway resistance is currently unknown. The aim of this study was to investigate tracheal pressure during capping or stoma button insertion and potential determinants concerning cuff. METHODS: Eight cuffed and uncuffed tracheostomy tubes and three stoma buttons of various manufacturers and sizes were inserted into the trachea model. Cuffs were completely deflated or contained atmospheric pressure. The trachea was ventilated bidirectional with a respirator in volume-controlled mode and volume flows 15-60 L/min. Tracheal pressure drop during inspiration as a parameter of pressure required to move gas through the airway was measured. RESULTS: Tracheal pressure drops occurred linearly or irregularly during capping trials to a maximum of 4.2 kPa at flow rates of 60 L/min for atmospheric pressure cuffs. In tracheostomy tubes with completely deflated cuffs, pressure drop in the trachea reaches a maximum of 3.4 kPa at a flow rate of 60 L/min. For tracheostomy tubes with cuff smaller inner or outer diameters do not regularly result in lower tracheal pressure drop. The pressure drop varies between different tracheostomy tubes depending on the manufacturer. In cuffed tracheostomy tubes, we observed three phenomena: sail-like positioning, folding over, and tightening of the cuff during flow. The maximum tracheal pressure drop during stoma button insertion reaches 0.014 kPa. CONCLUSIONS: The cuff is a central element for the pressure drop in the airway and thus airway resistance during spontaneous translaryngeal breathing with a capped TT. Complete deflation reduces the pressure drop in the trachea. Due to deformation of the cuff, measured pressures are irregular as the volume flow is increased. Incomplete deflated cuffs and material characteristics of tracheostomy tubes and cuffs in addition to anatomical and clinical variables may cause unsuccessful capping trials due to increased airway resistance. All stoma buttons showed that pressure drop and thus airway resistance due to stoma buttons has no clinical relevance.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。