Safety and efficacy of vacuum bottle plus catheter for drainage of iatrogenic pneumothorax

真空瓶加导管引流医源性气胸的安全性和有效性

阅读:1

Abstract

BACKGROUND: Iatrogenic pneumothorax is common after thoracic procedures. For patients with pneumothorax larger than 15%, simple aspiration is suggested. Although vacuum bottle plus non-tunneled catheter drainage has been performed in many institutions, its safety and efficacy remain to be assessed. METHODS: Through this prospective cohort study (NCT03724721), we evaluated the safety and efficacy of vacuum bottle plus non-tunneled catheter drainage. Patients older than 20 years old who developed post-procedural pneumothorax were enrolled. A non-tunneled catheter was placed at the intersection of the midclavicular line and the second intercostal space. A 3-way stopcock, a drainage set, and a digital pressure gauge were connected. The stopcock was manipulated to connect the pleural space to the pressure gauge for measurement of end-expiration intrapleural pressure or to the vacuum bottle for air drainage. The rate of successful drainage, the end-expiration intrapleural pressure before, during, and after the procedure and the duration of hospitalization were recorded. RESULTS: From August 2018 to February 2020, 21 patients underwent vacuum bottle plus catheter drainage (intervention group) and 31 patients received conservative treatment (control group). The end-expiration intrapleural pressure of all patients remained less than - 20 cmH(2)O during drainage. No procedure related complication was observed. Large pneumothorax (≥ 15%) was associated with higher risk of persistent air leak (Odds ratio 12, 95% CI 1.2-569.7). Vacuum bottle assisted air drainage yielded shorter event-free duration than that of conservative treatment (2 days vs 5 days [interquartile range 1-4 days vs 3-7 days], p < .05). Vacuum bottle assisted air drainage also help identifying patients with persistent pneumothorax and necessitate the subsequent management. The event-free duration of persistent air leak in the intervention group was also comparable with that of conservative treatment (5 days vs 5 days [interquartile range 5-8 days vs 3-7 days], p = .45). CONCLUSIONS: Vacuum bottle plus catheter drainage of iatrogenic pneumothorax is a safe and efficient procedure. It may be considered as an alternative management of stable post-procedural pneumothorax with size larger than 15%. Trial registration The study protocol was approved by the Research Ethics Committee of National Taiwan University Hospital (No. 201805105DINA) on 6th August, 2018. The first participant was enrolled on 23rd August, 2018 after Research Ethics Committee approval. This clinical trial complete registration at U.S. National Library of Medicine clinicaltrials.gov with identifier NCT03724721 and URL: https://clinicaltrials.gov/ct2/show/NCT03724721 on 30th October, 2018.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。