Preparation and Post-Processing of Three-Dimensional Printed Porous Titanium Alloys

三维打印多孔钛合金的制备及后处理

阅读:2

Abstract

Ti6Al4V is widely utilized in orthopedic implants due to its excellent mechanical properties, corrosion resistance, and biocompatibility. However, traditional solid titanium implants exhibit an elastic modulus (90-115 GPa) significantly higher than that of human bone (10-30 GPa), leading to stress shielding and implant loosening. To address this, porous titanium alloys have been developed to better match bone elasticity. Additive manufacturing, particularly selective laser melting (SLM), enables precise control over pore size and porosity, thereby tuning mechanical properties. Nevertheless, SLM-produced porous structures often suffer from powder adhesion, which compromises bone integration and patient safety. In this study, bulk Ti6Al4V samples were fabricated via SLM with a fixed laser power of 200 W and varying scanning speeds (800-1400 mm/s). Density measurements and surface defect analysis identified 1200 mm/s as the optimal scanning speed. Cubic unit cell scaffolds with different pore diameters (400, 600, 800 μm) and porosities (60%, 80%) were subsequently designed. Compression tests revealed that scaffolds with a 400 μm pore diameter and 60% porosity exhibited the highest compressive strength (794 MPa) and fracture strain (41.35%). Chemical polishing using a diluted HF-HNO(3) solution (1:2:97) effectively removed adhered powder without significant structural degradation, with 40 min identified as the optimal polishing duration.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。