Diagnostic value of contrast-enhanced ultrasonography in the preoperative evaluation of lymph node metastasis in papillary thyroid carcinoma: a single-center retrospective study

对比增强超声在乳头状甲状腺癌淋巴结转移术前评估中的诊断价值:一项单中心回顾性研究

阅读:1

Abstract

BACKGROUND: Contrast-enhanced ultrasound (CEUS) has been recently used for the assessment of cervical lymph node metastasis (LNM) to guide surgical operation in patients with papillary thyroid carcinoma (PTC). However, the specificity and sensitivity of CEUS reported from previous studies are not consistent. The objective of this study was to evaluate the diagnostic value of CEUS for the metastasis of cervical lymph nodes in PTC patients based on data from one regional central hospital. METHODS: The diagnostic value of CEUS in preoperative LNM of PTC patients was concluded by comparing the results of CEUS on lymph node status with postoperative pathology examination. In addition, this study conducted hierarchical analysis of PTC patients to explore whether tumor size, different lymph node regions, and Hashimoto's thyroiditis influence the assessment of CEUS. RESULTS: This research study ultimately enrolled 965 PTC patients, including 266 males and 699 females with a mean age of 42.27 ± 11.34 years. A total of 527 patients were considered clinical-node negative, and 438 were clinical-node positive before surgery. The specificity, sensitivity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of CEUS in the assessment of LNM in PTC patients were 56.00%, 71.00%, 57.06%, 69.76% and 62.59%, respectively. For central and lateral lymph nodes, the accuracy of CEUS in PTC patients was 49.43% and 54.30%, respectively. In addition, it was shown that the accuracy of CEUS in PTC patients with Hashimoto's thyroiditis (HT) slightly decreased to 58.44%, and the accuracy of CEUS in PTC patients with non-HT in turn increased to 64.17%. The accuracy of CEUS in non-papillary thyroid microcarcinoma (PTMC) and PTMC patients was 65.68% and 61.24%, respectively. The accuracy of CEUS in predicting central LNM was significantly different between PTC patients with or without HT (P < 0.001) in this study but not for lateral lymph nodes (P = 0.114). CONCLUSION: The accuracy of CEUS in the assessment of LNM in PTC is not consistently satisfactory, especially for central lymph nodes, small tumor diameters, or patients with HT. More diagnostic technologies for abnormal lymph nodes should be considered in PTC patients.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。