Cortical screw placement with a spinous process clamp guide: a cadaver study accessing accuracy

使用棘突夹导向器进行皮质螺钉置入:一项评估其准确性的尸体研究

阅读:1

Abstract

BACKGROUND AND OBJECTIVE: The Cortical Bone Trajectory (CBT) technique provides an alternative method for fixation in the lumbar spine in patients with osteoporosis. An accuracy CBT screw placement could improve mechanical stability and reduce complication rates. PURPOSE: The purpose of this study is to explore the accuracy of cortical screw placement with the application of implanted spinous process clip (SPC) guide. METHODS AND MATERIALS: Four lumbar specimens with T12-S1 were used to access the accuracy of the cortical screw. The SPC-guided planning screws were compared to the actual inserted screws by superimposing the vertebrae and screws preoperative and postoperative CT scans. According to preoperative planning, the SPC guide was adjusted to the appropriate posture to allow the K-wire drilling along the planned trajectory. Pre and postoperative 3D-CT reconstructions was used to evaluate the screw accuracy according to Gertzbein and Robbins classification. Intraclass correlation coefficients (ICCs) and Bland-Altman plots were used to examine SPC-guided agreements for CBT screw placement. RESULTS: A total of 48 screws were documented in the study. Clinically acceptable trajectory (grades A and B) was accessed in 100% of 48 screws in the planning screws group, and 93.8% of 48 screws in the inserted screws group (p = 0.242). The incidence of proximal facet joint violation (FJV) in the planning screws group (2.1%) was comparable to the inserted screws group (6.3%) (p = 0.617). The lateral angle and cranial angle of the planned screws (9.2 ± 1.8° and 22.8 ± 5.6°) were similar to inserted screws (9.1 ± 1.7° and 23.0 ± 5.1°, p = 0.662 and p = 0.760). Reliability evaluated by intraclass correlation coefficients and Bland-Altman showed good consistency in cranial angle and excellent results in lateral angle and distance of screw tip. CONCLUSIONS: Compared with preoperative planning screws and the actually inserted screws, the SPC guide could achieve reliable execution for cortical screw placement.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。