Totally implantable venous access devices: retrospective analysis of different insertion techniques and predictors of complications in 796 devices implanted in a single institution

完全植入式静脉通路装置:对单中心植入的796个装置的不同置入技术及并发症预测因素的回顾性分析

阅读:1

Abstract

BACKGROUND: The aim of this study was to assess the efficacy and safety of totally implanted vascular devices (TIVAD) using different techniques of insertion. METHODS: We performed a retrospective study using a prospective collected database of 796 consecutive oncological patients in which TIVADs were inserted. We focused on early and late complications following different insertion techniques (surgical cutdown, blind and ultrasound guided percutaneous) according to different techniques. RESULTS: Ultrasound guided technique was used in 646 cases, cephalic vein cutdown in 102 patients and percutaneous blind technique in 48 patients. The overall complication rate on insertion was 7.2% (57 of 796 cases). Early complications were less frequent using the ultrasound guided technique: arterial puncture (p = 0.009), technical failure (p = 0.009), access site change after first attempt (p = 0.002); pneumothorax occurred in 4 cases, all using the blind percutaneus technique. Late complications occurred in 49 cases (6.1%) which required TIVAD removal in 43 cases and included: sepsis (29 cases), thrombosis (3 cases), dislocation (7 cases), skin dehiscence (3 cases), and severe pain (1 case). CONCLUSION: Ultrasound guided technique is the safest option for TIVAD insertion, with the lowest rates of immediate complications.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。