Sparing Organs at Risk with Simultaneous Integrated Boost Volumetric Modulated Arc Therapy for Locally Advanced Non-Small Cell Lung Cancer: An Automatic Treatment Planning Study

采用同步集成增强容积调强弧形放疗保护局部晚期非小细胞肺癌的危及器官:一项自动治疗计划研究

阅读:1

Abstract

BACKGROUND: The technique of simultaneous integrated boost volumetric modulated arc therapy (SIB-VMAT) has been widely used in locally advanced non-small cell lung cancer; however, its dosimetric advantages are seldom reported. This study aimed to quantify dosimetric advantages of SIB-VMAT. METHODS: Forty patients with stage III non-small cell lung cancer in our hospital were retrospectively included. SIB-VMAT and conventional VMAT (C-VMAT) plans were generated for every patient using the automatic treatment planning system. A reduced dose was delivered to PTV in SIB-VAMT plans compared to C-VMAT plans (50.4Gy vs 60Gy). The prescribed dose was 50.4 Gy in 28 fractions to PTV and 59.92 Gy in 28 fractions to PGTV in SIB-VMAT plans, while 60 Gy in 30 fractions to PTV in C-VMAT plans. Dose-volume metrics of PTV, total lung, heart, esophagus and spinal cord were recorded. The quality score was used to evaluate organs at risk (OAR) protection for two type prescription plans. RESULTS: Conformal coverage of the targets (PGTV/PTV) by 95% of the prescription dose was well achieved in radiation plans. SIB-VMAT plans achieved significantly higher quality score than C-VMAT plans (Mean: 68.15±13.32 vs 49.15±13.35, P<0.001). More plans scored above sixty in SIB-VMAT group compared to C-VMAT group (72.5% vs 20%, P<0.001). Notable reductions in mean dose, V(30), V(40) and V(50) of total lung were observed in SIB-VMAT plans compared to C-VMAT plans, with median decreased proportions of 6.5%, 8.7%, 19.6% and 32.1%, respectively. Statistically significant decrease in heart V(30) and V(40) was also achieved in SIB-VMAT plans, with median decreased proportions of 26.1% and 38.8%. SIB-VMAT plans achieved significant reductions in the maximum doses to both esophagus and spinal cord. Patients with CTV/(GTV+GTVnd) ≥8.6 showed more notable decrease in total lung V(50) (median, 33.6% vs 28.8%, P=0.001) in SIB-VMAT plans compared to those with the ratio being less than 8.6. CONCLUSION: SIB-VMAT technique could lead to a substantial sparing of normal organs, including lung, heart, esophagus and cord, mainly through reducing high and inter-median dose exposure. Patients with CTV/(GTV+GTVnd) ≥8.6 might benefit more from SIB-VMAT.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。