One-year outcomes of polymer-free amphilimus-eluting stents versus durable polymer zotarolimus-eluting stents in patients with diabetes mellitus: a meta-analysis

糖尿病患者使用无聚合物安非他莫司洗脱支架与耐用聚合物佐他莫司洗脱支架的一年疗效比较:一项荟萃分析

阅读:1

Abstract

BACKGROUND: Diabetes mellitus (DM) and cardiovascular diseases often co-exist. Today, percutaneous coronary intervention (PCI) is the preferred revascularization procedure for majority of patients with coronary artery disease. Polymer-free amphilimus-eluting stents (AES) represent a novel elution technology in the current era of drug-eluting stents. In this analysis, we aimed to systematically compare the cardiovascular outcomes which are associated with polymer-free amphilimus-eluting stents (AES) versus the durable polymer zotarolimus-eluting stents (ZES) for the treatment of patients with DM. METHODS: Http://www. CLINICALTRIALS: gov, EMBASE, Web of Science, MEDLINE, Cochrane database and Google Scholar were searched for publications comparing polymer-free AES versus durable polymer ZES in patients with DM. Selective cardiovascular outcomes were assessed. Statistical analysis was carried out by the latest version of the RevMan software. Risk ratio (RR) with 95% confidence interval (CI) was used to represent the data analysis. RESULTS: Four studies with a total number of 1795 participants with DM whereby 912 patients were assigned to be revascularized by the polymer-free AES and 883 patients were assigned to be revascularized by the durable polymer ZES were included in this analysis. In patients with DM, at one year, polymer-free AES were associated with significantly lower risk of major adverse cardiac events (MACEs) (RR: 0.69, 95% CI: 0.54-0.88; P = 0.002) and target lesion failure (TLF) (RR: 0.66, 95% CI: 0.48-0.91; P = 0.01) compared to durable polymer ZES. However, there was no significant change in all-cause mortality (RR: 0.79, 95% CI: 0.51-1.22; P = 0.28), cardiac death and the other cardiovascular outcomes. Similar risk of total stent thrombosis (RR: 1.13, 95% CI: 0.60-2.13; P = 0.70), including definite stent thrombosis (RR: 1.12, 95% CI: 0.38-3.31; P = 0.84), probable stent thrombosis (RR: 0.87, 95% CI: 0.37-2.09; P = 0.76), possible stent thrombosis (RR: 1.19, 95% CI: 0.50-2.87; P = 0.69) and late stent thrombosis (RR: 1.00, 95% CI: 0.17-5.72; P = 1.00) as between polymer-free AES and durable polymer ZES in patients with DM. CONCLUSIONS: At 1 year follow-up, polymer-free AES were associated with significantly lower MACEs and TLF compared to durable polymer ZES in these patients with DM, without any increase in mortality, stent thrombosis and other cardiovascular outcomes. However, this analysis is only based on a follow-up time period of one year, therefore, future research should focus on the long term follow-up time period.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。