Transcatheter aortic valve implantation and surgical aortic valve replacement among hospitalized patients with and without type 2 diabetes mellitus in Spain (2014-2015)

西班牙住院患者中,2 型糖尿病患者和非糖尿病患者接受经导管主动脉瓣植入术和外科主动脉瓣置换术的情况(2014-2015 年)

阅读:2

Abstract

BACKGROUND: Type 2 diabetes mellitus (T2DM) is strongly related to the in-hospital and short-term prognosis in patients with cardiovascular diseases needing surgical or invasive interventions. How T2DM might influence the treatment of aortic stenosis (AS) has not been completely elucidated for surgical aortic valve replacement (SAVR) or transcatheter aortic valve implantation (TAVI). The aims of this study were: (1) to describe the use of aortic valve replacement procedures (TAVI and SAVR) among hospitalized patients with and without T2DM; and (2) to identify factors associated with in hospital mortality (IHM) among patients undergoing these procedures. METHODS: We analyzed data from the Spanish National Hospital Discharge Database between January 1, 2014 and December 31, 2015 for patients aged ≥ 40 years. We selected patients whose medical procedures included TAVI (ICD-9-CM codes 35.05, 35.06) and SAVR (ICD-9-CM codes 35.21, 35.22). We stratified each cohort by diabetes status: T2DM (ICD-9-CM codes 250.x0, 250.x2) and no diabetes. We retrieved data about specific comorbidities, risk factors, procedures, and specific in-hospital postoperative complications. Hospital outcome variables included IHM, and length of hospital stay (LOHS). RESULTS: We identified a total of 2141 and 16,013 patients who underwent TAVI (n = 715; 33.39% with T2DM) and SAVR (n = 4057; 25.33% with T2DM). In patients who underwent TAVI we found no differences in IHM (3.64% in T2DM vs. 5.12% in non-T2DM, p = 0.603). In the cohort of SAVR, mean LOHS was significantly lower in patients with T2DM than in non-diabetic patients (13.77 vs. 17.27 days). IHM was lower in patients with T2DM (4.36% vs. 6.31%, p < 0.01). After multivariable adjustment for both procedures, patients with T2DM had significantly lower IHM than patients without diabetes (adjusted OR 0.60; IC 95% 0.37-0.99 for TAVI and adjusted OR 0.80; IC 95% 0.66-0-96 for SAVR). CONCLUSIONS: T2DM diabetic patients with AS undergoing a valvular replacement procedure through SAVR or TAVI did not have a worse prognosis compared to non-diabetic patients during hospitalization, showing lower IHM after multivariable adjustment. However, given the limitations of administrative data more prospective studies and clinical trials aimed at evaluating the influence of these procedures in diabetic patients with AS are needed.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。