An artificial intelligence platform for the diagnosis and surgical planning of strabismus using corneal light-reflection photos

利用角膜光反射照片进行斜视诊断和手术规划的人工智能平台

阅读:1

Abstract

BACKGROUND: Strabismus affects approximately 0.8-6.8% of the world's population and can lead to abnormal visual function. However, Strabismus screening and measurement are laborious and require professional training. This study aimed to develop an artificial intelligence (AI) platform based on corneal light-reflection photos for the diagnosis of strabismus and to provide preoperative advice. METHODS: An AI platform consisting of three deep learning (DL) systems for strabismus diagnosis, angle evaluation, and operation plannings based on corneal light-reflection photos was trained and retrospectively validated using a retrospective development data set obtained between Jan 1, 2014, and Dec 31, 2018. Corneal light-reflection photos were collected to train the DL systems for strabismus screening and deviation evaluations in the horizontal strabismus while concatenated images (each composed of two photos representing different gaze states) were procured to train the DL system for operative advice regarding exotropia. The AI platform was further prospectively validated using a prospective development data set captured between Sep 1, 2019, and Jun 10, 2020. RESULTS: In total, 5,797 and 571 photos were included in the retrospective and prospectively development data sets, respectively. In the retrospective test sets, the screening system detected strabismus with a sensitivity of 99.1% [95% confidence interval (95% CI), 98.1-99.7%], a specificity of 98.3% (95% CI, 94.6-99.5%), and an AUC of 0.998 (95% CI, 0.993-1.000, P<0.001). Compared to the angle measured by the perimeter arc, the deviation evaluation system achieved a level of accuracy of ±6.6º (95% LoA) with a small bias of 1.0º. Compared to the real design, the operation advice system provided advice regarding the target angle within ±5.5º (95% LoA). Regarding strabismus in the prospective test set, the AUC was 0.980. The platform achieved a level of accuracy of ±7.0º (95% LoA) in the deviation evaluation and ±6.1º (95% LoA) in the target angle suggestion. CONCLUSIONS: The AI platform based on corneal light-reflection photos can provide reliable references for strabismus diagnosis, angle evaluation, and surgical plannings.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。