Evaluation of the linear interpolation method in correcting the influence of slice thicknesses on radiomic feature values in solid pulmonary nodules: a prospective patient study

评估线性插值法在校正层厚对实性肺结节放射组学特征值的影响方面的有效性:一项前瞻性患者研究

阅读:1

Abstract

BACKGROUND: To investigate the influence of slice thickness on radiomic feature (RF) values in solid pulmonary nodules and evaluate the effect of a linear interpolation method in correcting the influence. METHODS: Thirty pulmonary nodules from 28 patients were selected prospectively with a thick-slice of 5 mm and a thin-slice of 1.25 mm on CT. A resampling method was used to normalize the voxel size of thick and thin slices CT images to 1×1×1 mm(3) by linear interpolation. Lung nodules were segmented manually. A total of 396 radiomic features (RFs) were extracted from thick-slice and thin-slice images, together with the images resampled from thick (thick-r) and thin (thin-r) slices. The differences between the RF values were evaluated using a paired t-test. A comparison between groups was made using the Chi-squared test. RESULTS: Among the 396 RFs, 305 RFs showed an intraclass correlation coefficient ≥0.75 after test-retest analysis (including 22 histogram features, 20 geometry features, and 263 texture features). In the non-resampled data, 239 RF values (78.4%, 239/305) showed significant differences between thick and thin slice CT images. Resampling of thick images revealed that 202 RF values (66.2%, 202/305) showed significant differences between thick-r and thin slice CT images, showing a significant decrease in the number of different RF values when compared to non-resampled data (P<0.01). For the RF subgroups, only texture features showed a significant reduction in the number of different RF values after resampling (P<0.01). When both thick and thin slice images were resampled, the number of significantly different RF values between thick-r and thin-r images was increased to 247 (81.0%, 247/305), showing no significant difference when compared to non-resampled data (P=0.421). CONCLUSIONS: Slice thickness demonstrated a considerable influence on RF values in solid pulmonary nodules, producing false results when CT images with different slice thicknesses were used. Linear interpolation of the resampling method was limited because of the relatively small correction effect.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。