A hook-effect-free homogeneous light-initiated chemiluminescence assay: is it reliable for screening and the quantification of the hepatitis B surface antigen?

一种无钩状效应的均相光引发化学发光测定法:它是否可用于乙型肝炎表面抗原的筛查和定量?

阅读:1

Abstract

BACKGROUND: Hepatitis B virus (HBV) infection remains a threat to global public health. As a hallmark of HBV infection, hepatitis B surface antigen (HBsAg) has been used to screen for HBV infection for decades, and quantitative assays are also being clinically rejuvenated to predict the disease outcome and monitor the antiviral response. Herein, we developed and evaluated a hook-effect-free homogeneous quantitative HBsAg assay based on the light-initiated chemiluminescence immunoassay (LICA). METHODS: A hook-effect-free LICA algorithm was established by measuring the relative light units (RLUs) of two time points during the immunoreaction. The precision was assessed using low- and high-level controls. Consecutive clinical serum samples were tested using the LICA and Abbott Architect assay; samples producing inconsistent results were retested using supplementary assays including the HBsAg neutralization, HBV DNA, and Roche Elecsys HBsAg assays for further confirmation. The consistency, sensitivity, specificity, and positive and negative predictive values (PPV and NPV) were calculated. For the quantitative results, the correlation was analyzed. The coverage of different genotypes and mutations by the LICA was evaluated. Moreover, serial on-treatment and follow-up samples from chronic hepatitis B patients were also measured using the two assays. RESULTS: The LICA had better within-run and within-laboratory precisions than the Architect assay. In total, 5,176 clinical samples were tested. The two assays showed a consistency of 99.63%. The LICA showed greater specificity (99.95% vs. 99.77%) and PPV (99.75% vs. 98.77%) than the Architect assay, whereas the Architect assay showed greater sensitivity (100.00% vs. 99.01%) and NPV (100.00% vs. 99.82%). The two assays displayed an excellent correlation independent of genotypes and mutations. The LICA hook-free algorithm recognized 100% of the underestimated results. Furthermore, similar HBsAg dynamics were demonstrated using the LICA and Architect HBsAg assay. CONCLUSIONS: The hook-free LICA provides a reliable tool for screening for HBV infection and quantifying HBsAg.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。