Internet of things-based management versus standard management of home noninvasive ventilation in COPD patients with hypercapnic chronic respiratory failure: a multicentre randomized controlled non-inferiority trial

物联网管理与标准管理在伴有高碳酸血症慢性呼吸衰竭的慢性阻塞性肺疾病患者家庭无创通气治疗中的比较:一项多中心随机对照非劣效性试验

阅读:4

Abstract

BACKGROUND: Effective monitoring and management are crucial during long-term home noninvasive positive pressure ventilation (NPPV) in patients with hypercapnic chronic obstructive pulmonary disease (COPD). This study investigated the benefit of Internet of Things (IOT)-based management of home NPPV. METHODS: This multicenter, prospective, parallel-group, randomized controlled non-inferiority trial enrolled patients requiring long-term home NPPV for hypercapnic COPD. Patients were randomly assigned (1:1), via a computer-generated randomization sequence, to standard home management or IOT management based on telemonitoring of clinical and ventilator parameters over 12 months. The intervention was unblinded, but outcome assessment was blinded to management assignment. The primary outcome was the between-group comparison of the change in health-related quality of life, based on severe respiratory insufficiency questionnaire scores with a non-inferiority margin of -5. This study is registered with Chinese Clinical Trials Registry (No. ChiCTR1800019536). FINDINGS: Overall, 148 patients (age: 72.7 ± 6.8 years; male: 85.8%; forced expiratory volume in 1 s: 0.7 ± 0.3 L; PaCO(2): 66.4 ± 12.0 mmHg), recruited from 11 Chinese hospitals between January 24, 2019, and June 28, 2021, were randomly allocated to the intervention group (n = 73) or the control group (n = 75). At 12 months, the mean severe respiratory insufficiency questionnaire score was 56.5 in the intervention group and 50.0 in the control group (adjusted between-group difference: 6.26 [95% CI, 3.71-8.80]; P < 0.001), satisfying the hypothesis of non-inferiority. The 12-month risk of readmission was 34.3% in intervention group compared with 56.0% in the control group, adjusted hazard ratio of 0.56 (95% CI, 0.34-0.92; P = 0.023). No severe adverse events were reported. INTERPRETATION: Among stable patients with hypercapnic COPD, using IOT-based management for home NPPV improved health-related quality of life and prolonged the time to readmission. FUNDING: Air Liquide Healthcare (Beijing) Co., Ltd.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。